FANUC Troubleshooting and Support is back with a "How-To" on the FANUC Series 16/18 Backup and Restore Procedure. Please read the information below for full details. FANUC Series 16/18 Backup & Restore Procedure – Data In/Out Operation Output the following data when it is possible in normal conditions. a. CNC parameter b. Pitch error compensation [...]
**warning: holding down 7 and 9 keys while powering on the control will clear/delete all existing memory in the contorl** 1) Hold down keys 7 and 9 while powering on the control to dump memory/clear file. Control will then come up in IPL mode. Hold down the . and – keys, while powering on the [...]