B–65245EN/02 START–UP PROCEDURE 3. START–UP PROCEDURE 3.4 PARAMETER INITIALIZATION (1) Preparation prior to servo parameter initialization Before servo parameter initialization, check the following: Servo motor model (Example: β 6/2000) Amount of travel per motor rotation (Example: 10 mm/motor revolution) Number of pulses per motor rotation (Example: 10000 pulses/motor revolution) A detection unit is determined from [...]
Read more
- by Development
- June 9, 2022
aiS series servo motor Motor model Motor specification Motor ID No. 90D0 90E0 90B0 90B5 90B6 90B1 9096 HRV1 HRV2 aiS2/5000 0212 162 262 A H A A A aiS2/6000 0218 - 284 G - B B - aiS4/5000 0215 165 265 A H A A A aiS8/4000 0235 185 285 A H A A [...]
Read more
- by Development
- June 9, 2022
Alarm code27 The sensor signal (position coder signal) for position control is abnormal. <1> The signal of the a position coder is disconnected (for all types). <2> When an MZ or BZ sensor is used with SPM TYPE1 (using the JY2 connector), the amplitude of the sensor signal is excessively small. <3> When a separate [...]
Read more
- by Development
- June 9, 2022
ALARM 414 (DIGITAL SERVO SYSTEM IS ABNORMAL) Points Check details by CNC’s diagnostic function and LED display on the servo amplifier. 1) 2) LED display on the servo amplifier 3) • When DGN200 shows “1” #6(LV): Low voltage alarm ® LED [2] or [3]lights #5(OVC): Over current alarm #4(HCA): Abnormal current alarm ‹ LED [8] [...]
Read more
- by Development
- June 9, 2022
ALARM 970 (NMI ALARM IN PMC CONTROL MODULE) RAM parity error or NMI has occurred in the PMC control module. Causes and Remedies Fault of PMC module is considered. . PMC control module (3) is faulty. . DRAM module (9) is faulty. Module mounting position Content Credit: FANUC Product Manual
Read more
- by Development
- June 8, 2022
Welcome to Parts Provider's dedicated page for Alpha-I SPM Alarm Codes. Here, you will find a comprehensive FANUC alarm codes list tailored to help you quickly identify and troubleshoot issues with your machinery. Our detailed table provides each alarm code, followed by an in-depth explanation to assist you in understanding and resolving any problems efficiently. [...]
Read more
- by Development
- June 7, 2022
Causes and actions A fault occurred on the FSSB (serial servo bus) that connects servo amplifiers to the CNC. This alarm is issued if a fault occurs in any of the axis control cards making up the FSSB, optical cables, and servo amplifiers. • Identifying the defective location Use the LEDs on the servo amplifiers. [...]